Examination
Turn on the ignition. The stop device should click.
If it doesn't, disconnect the wire (A). Using the auxiliary wire, connect the stop device to the positive terminal of the battery.
If in this case the solenoid valve works, check the electrical connections and wires, the voltage supply from the control unit.
If the valve does not work, check the tightness of the engine stop device and, if necessary, replace it.
Removing
Disconnect the negative cable from the battery with the ignition off. This erases the data from the electronic memory units. See instructions in chapter «electrical equipment».
Disconnect electrical wires. Clean the stop device from the outside and unscrew it.
Attention: Make sure that the piston and spring do not fall out.
Installation
Insert the stop device with a new O-ring. Pay attention to the correct fit of the spring and piston.
Carefully screw the stop device into the injection pump and tighten to 20 Nm.
Connect wire to solenoid valve. Set the clock and enter the required codes.