2. Make sure the battery is charged.
3. If the starter still does not work, then the problem is in the main contacts of the traction relay or in the starter itself.
4. If the solenoid plunger does not click when the switch is actuated, the traction relay is defective or the solenoid circuit is open.
5. To check the engine, connect a jumper to the battery (IN) and solenoid clamp M. If the starter now works, the engine is good and the problem is in the traction relay, the ignition switch or in the wiring.
Starter check
6. If the starter still does not work, remove the starter and solenoid assembly for testing, repair, or replacement.