Basic data
Radiator cap release valve pressure: 0.93-1.23 bar
Thermostat:
- Temperature at the beginning of opening is 80.6-84.6°C
- Fully open temperature: 95.8°C
Refrigerant type:
- 1993 models - R-12
- Models produced since 1994 - R134a
The filling volume of the air conditioning system is 0.9 kg
Tightening torques for connections N·m
Thermostat housing bolts - 19-24
Water pump mounting bolts to the block — 19-24
Water pump pulley bolts - 10
Inlet manifold bolts - 19-24