Figure 14.31. Removing the air valves (1) of the RVT system
Remove the pressure plate mounting bolts, disconnect the vacuum hoses and remove the valves from the air cleaner (figure 14.31).
To check the valve, it is necessary to use a vacuum pump. Connect the valve with a piece of tubing, then slowly increase the vacuum and check that the valve begins to open at a pressure of 70–90 mmHg.
Installation is carried out in the reverse order of removal.